PLF HGB

Plasma Free Hemoglobin

EPIC Test Procedure Code: LAB6992

Performing Lab:
Saint Luke's Regional Laboratories
Required Patient Info:
IF THE ORDER IS FOR A RESEARCH PATIENT, THE CORRECT TEST IS:

https://www.saintlukeskc.org/lab-test-directory/plasma-free-hemoglobin-study-patients-only

Container Type:
Green top (heparin) tube
Specimen Type:

Plasma

Preferred Volume:
1 mL
Minimum Volume:
0.2 mL
Specimen Processing:
  1. Centrifuge and separate the plasma from the cells immediately following collection.
  2.  Re-spin plasma for an additional 10 minutes.
  3. Remove plasma and place in another tube and cap.
Store and Transport:
Room temperature
Stability:

Refrigerated - 24 hours
Room temperature - 24 hours

Unacceptable Condition:

Frozen specimens will be rejected
Very icteric or lipemic specimens will be rejected
Non-heparinized plasma samples will be rejected

CPT Codes:

83051 - Hemoglobin Plasma Free (EAP 30131999)

Method:
HemoCue Plasma Low Hemoglobin III
Reference Ranges:

<30

mg/dL

Critical:

>70

mg/dL