SEROTON

Serotonin

EPIC Test Procedure Code: LAB3427

Performing Lab:
Referral Laboratory
Patient Preparation:

Monoamine oxidase inhibitor drugs should be discontinued for at least one week prior to sampling since they tend to increase the level of serotonin.

Container Type:
Red top tube or gel-barrier tube
Specimen Type:

Serum

Preferred Volume:
1 mL
Minimum Volume:
0.5 mL
Specimen Processing:

Separate the serum from the cells within 30 minutes of collection.
 

Store and Transport:
Room temperature
Stability:

Frozen - 14 days
Refrigerated - 7 days
Room temperature - 7 days

Unacceptable Condition:

Plasma specimens or serum not separated from the cells.

CPT Codes:

84260 - Serotonin (EAP 30021123)

Method:
Liquid chromatography/tandem mass spectrometry (LC/MS-MS)
Reference Ranges:

Please refer to the performing lab report for applicable reference ranges

Lab Personnel

Please login to see billing, ordering, and reporting instructions.