PROT C ACT
Protein C, Functional
EPIC Test Procedure Code: LAB2356
Performing Lab:
Saint Luke's Regional Laboratories
Container Type:
Light blue top (sodium citrate) tube
Specimen Type:
Platelet Poor Plasma
Preferred Volume:
2 mL
Minimum Volume:
1 mL
Collection Procedure:
Specimen Processing:
1. Centrifuge specimen in a centrifuge that has been validated to ensure platelet poor plasma.
2. Immediately transfer the plasma to a stoppered, plastic tube and centrifuge again for 10 minutes.
3. Transfer the supernatant plasma into a screw-capped, plastic vial and send at ≤ -20° C, if possible.
4. If unable to centrifuge, forward unprocessed sodium citrate whole blood (minimum volume: 2 mL) to the laboratory promptly at room temperature only.
Store and Transport:
Frozen (plasma)
Stability:
The unspun specimen must arrive within 2 hours of collection.
CPT Codes:
85303 - Protein C Functional (EAP 30022380)
85302 - Protein C antigen (if appropriate)
Test Schedule:
Monday - Friday
Method:
Chromogenic
Test Includes:
If "Protein C Activity" is < 70 % and patient is not on warfarin, "Protein C Antigen" will be performed and charged.
Reference Ranges:
70 - 150 %