MG24U

Magnesium, Urine

EPIC Test Procedure Code: LAB3263

Performing Lab:
Referral Laboratory
Container Type:
Plastic urine container with 30 mL 6 N HCL
Specimen Type:

24 hour urine collection. Alternately, a pour-off sample from a 24 hour urine collection is acceptable but client must measure 24 hour urine volume and indicate the amount on the requisition.

Preferred Volume:
5 mL
Minimum Volume:
2.2 mL
Collection Procedure:

24 Hour Urine Collections:—Collect as follows:
1. To begin the collection, empty the bladder and discard this urine. Record this time and date as the start of the collection.
2. 24 hour urine collections should be started Sunday through Thursday.
3. Collect all urine excreted during the next 24 hours in the urine collection container.
4. Exactly 24 hours after the collection was begun, empty the bladder for the last time. Add this urine to the 24 hour urine container. The collection is finished.
5. The container should be refrigerated during and after the 24 hour collection period until it can be brought to Saint Luke’s Regional Laboratories.

Specimen Processing:

1. The request form must state the 24 hour urine volume.
2. Enter the urine volume into the MLAB prompt.

Store and Transport:
Room temperature
Stability:

Frozen - 14 days
Refrigerated - 14 days
Room temperature - 14 days

Unacceptable Condition:

Causes for rejection include the presence of blood in the urine and no preservative in the urine collection container.

CPT Codes:

83735 - Magnesium 24 HR Urine (EAP 30020577)
81050 - Urine Volume Measurement (EAP 30033360)

Method:
Colorimetric, Xylidyl Blue

Lab Personnel